F61 Series
Adaptor Plate Assembly
INSTALLATION INSTRUCTIONS
WHITE-RODGERS
Operator: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
This adaptor plate assembly is designed for mounting a
1F6X, 1F7X, or 1F9X series thermostat to the wall or to a
junction box. The wall cover plate covers the junction box,
wall damage, or old thermostat markings. The adaptor
plateisdesignedtoallowhorizontalthermostatmounting,
regardless of junction box orientation.
Adaptor Plate
5
” Phillips
16
All kits may not have adaptor plate or all screws shown.
No. 6 X
pan-head screw (2)
⁄
3
6-19 X
⁄
” Phillips
8
pan-head screw (3)
3
Wall Cover
Plate
6-32 X
⁄
” flat-head
4
machine screw (4)
PRECAUTIONS
CAUTION
NOTE
!
To prevent electrical shock and/or equip-
ment damage, disconnect electrical power
at main fuse or circuit breaker until installa-
tion is complete.
This instruction sheet is not intended as a wiring guide.
Refer to the thermostat installation instructions to ensure
proper wiring.
CONTENTS
Description ......................................................... 1
Precautions ........................................................ 1
Installation.......................................................... 2
For 1F9X Digital Thermostats
For 1F7X Quartz Clock Thermostats
For 1F6X Thermostats
WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
PART NO. 37-5148B
Printed in U.S.A.
Replaces 37-5148A
9607
ST. LOUIS, MISSOURI 63123-5398
NOTE
When installing wall cover plate and thermostat directly to
wall, usethepointedscrewssuppliedwiththethermostat.
No. 6 X 1” pan-head screws
(supplied with thermostat)
Wall
Wall Cover Plate
Thermostat Subbase
Thermostat
Figure 3. Mounting 1F9X digital thermostat to wall
FOR 1F7X QUARTZ CLOCK THERMOSTATS
NOTE
Do not install the wall mounting plate and subbase at the
sametime.Thethermostatwillnotoperateproperlyifboth
wall mounting plate and subbase are installed.
FAN
ON
AUTO
3
6-32 X ⁄ ” flat-head
4
Junction Box
SYSTEM
COOL
OFF
machine screws
HEAT
3
6-32 X ⁄ ” flat-head
4
machine screws
Thermostat
Subbase*
Wall Cover Plate
1
2
9
3
DA
Y
6
50
6
60
3
70
80
90
9
2
1
*Do not use both subbase and wall
mounting plate – see note, above.
90
HI
80
70
Wall Mounting
Plate*
LO
60
50
Thermostat
Figure 4. Mounting 1F7X quartz clock thermostat to horizontal junction box
3
NOTE
Locate and drill two
clearance holes in wall
Do not install the wall mounting plate and subbase at the
sametime.Thethermostatwillnotoperateproperlyifboth
wall mounting plate and subbase are installed.
3
6-32 X ⁄ ” flat-head
4
machine screws
Junction Box
FAN
ON
AUTO
3
6-32 X ⁄ ” flat-head
4
SYSTEM
COOL
machine screws
OFF
Adaptor Plate
HEAT
3
6-32 X ⁄ ” flat-head
4
machine screws
Thermostat
Subbase*
Wall Cover Plate
1
2
9
3
DA
Y
6
50
6
60
3
70
80
90
9
2
1
*Do not use both subbase and wall
mounting plate – see note, above.
90
HI
80
70
Wall Mounting
Plate*
LO
60
50
Thermostat
Figure 5. Mounting 1F7X quartz clock thermostat to vertical junction box
NOTE
NOTE
Do not install the wall mounting plate and subbase at the When installing wall cover plate and thermostat directly to
sametime.Thethermostatwillnotoperateproperlyifboth wall, usethepointedscrewssuppliedwiththethermostat.
wall mounting plate and subbase are installed.
FAN
ON
AUTO
SYSTEM
COOL
No. 6 X 1” pan-head screws
(supplied with thermostat)
OFF
HEAT
Wall
No. 6 X 1” pan-head screws
(supplied with thermostat)
Wall Cover Plate
Thermostat
Subbase*
1
2
9
3
DA
Y
6
50
6
60
3
70
9
2
1
80
90
*Do not use both subbase and wall
mounting plate – see note, above.
90
80
70
60
50
HI
Wall Mounting
Plate*
LO
Thermostat
Figure 6. Mounting 1F7X quartz clock thermostat to wall
4
FOR 1F6X THERMOSTATS
3
6-32 X ⁄ ” flat-head
4
machine screws
Junction Box
3
No. 6 X ⁄ ” Phillips
8
pan-head screws
Instructions Inside Cover
Wall Cover Plate
Thermostat
Thermostat Cover
Figure 7. Mounting 1F60 thermostat to horizontal junction box
Locate and drill two
clearance holes in wall
3
6-32 X ⁄ ” flat-head
4
machine screws
Junction Box
3
6-32 X ⁄ ” flat-head
4
machine screws
Adaptor Plate
3
No. 6 X ⁄ ” Phillips
8
pan-head screws
TIME
SET
SET
BACK
COOL OHEAT
Wall Cover Plate
0
0
3
5
6
9
10 15
°
C
F
°
AUTO CONT.
FAN
Thermostat
Thermostat Cover
Figure 8. Mounting 1F60 thermostat to vertical junction box
5
NOTE
When installing wall cover plate and thermostat directly to
wall, usethepointedscrewssuppliedwiththethermostat.
No. 6 X 1” pan-head screws
(supplied with thermostat)
3
No. 6 X ⁄ ” Phillips
8
pan-head screws
Wall
AM
PM
SETBACK
Instructions Inside Cover
TIME
SET
HEAT
COOL
SET
BACK
COOL OHEAT
Wall Cover Plate
0
0
3
5
6
9
10 15
WHIT-RODGERS
°
C
°
F
AUTO CONT.
FAN
50
60 70 80 90
°
32
F
10
21
°
C
Thermostat
Thermostat Cover
Figure 9. Mounting 1F60 thermostat to wall
3
6-32 X ⁄ ” flat-head
4
machine screws
Junction Box
3
No. 6 X ⁄ ” Phillips
8
pan-head screws
Wall Cover Plate
CLEAR
SET
BACK
AM
PM
TIME
SET
SETBACK
HEAT
Instructions Inside Cover
COOL OFF HAT EMHT
Thermostat Subbase
COMPRESSOR
MALFUNCTION
COOL
EMERGENCY
HEAT
0
0
3
5
6
9
10 15
°
C
AUXILIARY
HEAT
°
F
AUTO CONT.
FAN
60
65
WHITRODGERS
70 21
75
55
Thermostat
(connect harness –
snap onto subbase)
80
10 50
85
90 32
°
F
°
C
Thermostat Cover
Figure 10. Mounting 1F62 thermostat to horizontal junction box
6
Locate and drill two
clearance holes in wall
3
6-32 X ⁄ ” flat-head
4
machine screws
3
6-32 X ⁄ ” flat-head
4
Junction Box
Adaptor Plate
machine screws
3
No. 6 X ⁄ ” Phillips
8
pan-head screws
Wall Cover Plate
CLEAR
SET
BACK
AM
PM
TIME
SET
SETBACK
HEAT
Instructions Inside Cover
COOL OFF HAT EMHT
Thermostat
Subbase
COMPRESSOR
MALFUNCTION
COOL
EMERGENCY
HEAT
0
0
3
5
6
9
10 15
°
C
F
AUXILIARY
HEAT
°
AUTO CONT.
FAN
60
65
WHIT-RODGERS
70 21
75
55
Thermostat
(connect harness –
snap onto subbase)
80
10 50
85
90 32
°
F
°
C
Thermostat Cover
Figure 11. Mounting 1F62 thermostat to vertical junction box
NOTE
When installing wall cover plate and thermostat directly to
wall, usethepointedscrewssuppliedwiththethermostat.
No. 6 X 1” pan-head screws
(supplied with thermostat)
3
No. 6 X ⁄ ” Phillips
8
pan-head screws
Wall
Wall Cover Plate
CLEAR
SET
BACK
AM
PM
TIME
SET
SETBACK
HEAT
Instructions Inside Cover
COOL OFF HAT EMHT
Thermostat
Subbase
COMPRESSOR
MALFUNCTION
COOL
EMERGENCY
HEAT
0
0
3
5
6
9
10 15
°
C
AUXILIARY
HEAT
°
F
AUTO CONT.
FAN
60
65
WHIT-RODGERS
70 21
75
55
Thermostat
(connect harness –
snap onto subbase)
80
10 50
85
90 32
°
F
°
C
Thermostat Cover
Figure 12. Mounting 1F62 thermostat to wall
7
If you need further information about this product, please write to
White-Rodgers Division, Emerson Electric Co.
9797 Reavis Road
St. Louis, MO 63123-5398
Attention: Technical Service Department
|